DeVilbiss PD1000 Conserving Device
Featuring PulseDose technology, the PD1000 is a smaller, more compact and attractive unit. With an extremely lightweight design and true 3:1 savings, the PD1000 delivers high efficiency and improved clinical benefits. It features quiet operation and has been found to be less irritating to patients. Impact-resistant materials are used in the conserver's outer covering making it not only durable but attractive as well.
The DeVilbiss PD1000 Compact Conserving Device is intended as a delivery device for medical-grade oxygen from high-pressure oxygen cylinders. This is an ambulatory device, which allows patients to ambulate longer than they would with a continuous flow regulator on the same cylinder.
How Pulsedose works:
PulseDose dramatically extends the use time from a supply of oxygen, offering increased mobility with improved comfort and increased efficiency. The reliability and safety of PulseDose oxygen delivery has been proven effective in clinical testing.
Because oxygen is released only during inhalation, the constant flow of oxygen into the nostrils is eliminated. Many users find PulseDose oxygen delivery more comfortable than continuous flow delivery systems. The short “pulse” of oxygen delivered during inhalation is almost undetectable, and the humidity in the room air helps maintain a normal level of moisture in the nasal cavity. This greatly reduces the discomfort of dehydration associated with a continuous flow oxygen system.
Features of the DeVilbiss PD1000 Compact Conserving Device :
- Clinical superiority of PulseDose Technology
- True 3:1 savings
- 3-year warranty
- Single lumen cannula
- Lightweight
- Compact size
- Impact-resistant GE Lexan® case
- Easy-to-use single control
- Field serviceable & protected cannula fitting
Specifications of the DeVilbiss PD1000 Compact Conserving Device :
Built to meet the requirements of HCPCS code: |
A9999 |
Product Weight: |
16.3 oz. (with batteries) |
Product Width: |
8.64cm |
Product Length/Depth: |
12.06cm |
Product Height: |
2.8 in. |
Power Supply: |
(2) Standard "AA" alkaline or NiMH batteries |
Power Requirements: |
Batteries other than alkaline or NiMH are not recommended due to the capacity needed for operation and battery life of the unit. |
Operating Temperature Range: |
5 to 40 deg. C (41 to 104 deg. F) |
Operating Pressure Range: |
500 to 2250 PSIG tank pressure |
Operating Humidity Range: |
0 to 95% R.H., non-condensing |
Storage and Transportation Temperature Range: |
-20 to 60 deg. C (-4 to 140 deg. F) |
Storage and Transportation Humidity Range: |
Up to 95% R.H., non-condensing |
Modes of Operation: |
Continuous / Pulsed |